A B C D E F G H I J Okay L M N O P Q R S T U V W X Y Z
A
Absorbed Dose
Adaptive Array, CT Detectors
Adaptive Histogram Equalization
Adaptive Multi-Planar Reconstruction (AMPR), MDCT
Adaptive Statistical Iterative Reconstruction (ASIR)
Added Filtration
Further Filtration
Superior Single-Slice Rebinning (ASSR), MDCT
Aliasing
Alpha Mixing
AMBER
Ambient Gentle
Amorphous Selenium (a-Se)
Amorphous Silicon (a-Si)
Angiography
Angular Beam Modulation (ABM)
Anode Angle
Anthropomorphic Phantom
Antimony Trisulfide
Array Processor
Facet Ratio
Atomic Quantity
Attenuation of X-Rays
Computerized Brightness Management (ABC)
Computerized Dose Fee Management (ADRC)
Computerized Publicity Management (AEC)
Computerized Publicity Management (AEC), Mammography
Computerized Publicity Management (AEC), MDCT
Computerized Achieve Management (AGC)
Axial Projection
#prime
B
Background Equal Radiation Time (BERT)
Background Radiation
Again Projection
Backscatter
Bandpass Filter
Band Idea
Barium Distinction Media
Barium Fluorohalide
Beam Filtration
Beam Hardening
Beer-Lambert Legislation
Binding Vitality
Biomolecular Harm
Bolus Chasing, DSA
Bone Attenuation
Bremsstrahlung
Brightness Achieve
Bucky Issue
#prime
C
Cadmium Selenide
Digicam Management Unit (CCU)
C-Arm CT
C-Arm Methods
CCD, Mammography
CCD Video Digicam
Cesium Bromide
Cesium Iodide
Chalnicon
Attribute Radiation
Cost-Coupled Gadget (CCD)
CMOS
Coherent Scatter
Collimator
Collimation, Digital
Color Look-Up Desk (CLUT)
Composite MPR Show
Compression, Mammography
Compton Impact
Computed Radiography (CR)
Computed Tomography (CT)
Computerized Axial Tomography (CAT)
Cone-Beam CT
Cone-Beam Reconstruction Algorithm (COBRA), MDCT
Distinction-Element Analysis
Distinction Enhancement
Distinction, Picture
Distinction, Topic
Distinction, Scatter Results
Conversion Effectivity
Convolution Filter
Coordinate Switch Perform (CTF)
Copper Filtration
Coronal Reconstruction
Cosmic Radiation
CT Fluoroscopy (CTF)
CT, Helical
CT Picture Show
CT Picture Reconstruction
CT-Quantity
CT, Spiral
Curved Reconstruction
Minimize-Off Frequency
#prime
D
Densitometric Evaluation, DSA
Detection Effectivity
Detection of X-Rays
Detective Quantum Effectivity (DQE)
Deterministic Well being Threat
Diagnostic Reference Ranges (DRLs)
DICOM
Digital Picture Illustration
Digital Pictures
Digital Picture Processing
Digital Picture Processor
Digital Radiography (DR)
Digital Radiography, Direct Receptors
Digital Radiography, Oblique Receptors
Digital Subtraction Angiography (DSA)
DNA Harm
Dose-Space Product – Fundamentals; Location; KERMA-Space Product (KAP);
Utility
Dose, Eyes
Dose Limits
Dose Discount, Radiography
Dose Discount, Fluoroscopy
Double Strand Breaks
DSA Picture Processor
DSA Instrumentation
Twin-Vitality CT (DECT)
Twin-Vitality Radiography
Twin-Vitality X-Ray Absorptiometry (DEXA)
Twin-Supply CT (DSCT
Dynamic Vary
#prime
E
ECG_Gating, MDCT
Edge Enhancement
Efficient Dose
Efficient Doses, from Radiography
Efficient Doses, from Fluoroscopy
Electromagnetic Radiation
Enhanced Visualization Processing (EVP)
Entrance Pores and skin Dose (ESD)
Epidemiological Research
Epilation
Equal Dose
Erythema
Publicity
Publicity Creep
Publicity Index (EI)
Additional-Focal Radiation
Eye Safety
#prime
F
Feldkamp Algorithm
Fibre Optic Taper
Filament Cathode
Fill Issue
Filter, X-Ray Beam – Aluminium, Copper, Molybdenum, Uncommon-Earth, Rhodium, Spectral
Filter, Digital Picture Processing – Convolution, Kernel, Temporal, Spatial
Filtered Again Projection (FBP)
Flat Discipline Correction
Fluorescence
Fluorescent X-Ray
Fluorography Publicity
Fluoro Noise Discount (FNR)
Fluoroscopic Loop
Fluoroscopy Burn
Fluoroscopy Publicity
Fluoroscopy, Pulsed
Fluoroscopy Methods
Flux Achieve
Flying Focus XRT
Fly-Via
Focal Spot
Focal Spot, Efficient Measurement
Focussing Cup
Fourier Filtering
Fourier Rework
Free Radicals
#prime
G
Gadolinium Oxysulfate
Gamma
Gaussian Filter
Common Radiography
Geometric Evaluation, DSA
Geometric Magnification
Grey (Gy)
Grids
Grids, Mammography
Grids, Moiré Patterns
Greyscale
Greyscale Normal Show Perform (GSDF)
#prime
H
Half Worth Layer
Heating Capability, XRT
Heel Impact
Helical CT
Excessive-Move Filter
Histogram Equalization
Hounsfield Unit (HU)
HV Generator
HV Generator, Falling Load
HV Generator, Inverter
HV Generator, Inverter with AEC
HV Generator, Medium Frequency
HV Generator, Single Part
HV Generator, Three Part
HV Generator, Capacitative Discharge
#prime
I
Picture Compression
Picture Distinction
Picture Deconvolution
Picture Show
Picture Distortion
Picture Fusion
Picture Noise
Picture Noise, DSA
Picture High quality
Picture Reconstruction, CT
Picture Quantization
Picture Registration
Picture Sampling
Picture Segmentation
Picture Storage & Distribution
Picture Superimposition
Imaging Geometry
Inherent Filtration
Enter Phosphor
Built-in Masks-Mode DSA
Interlaced Raster Scan
Interpolation, Helical CT
Inverse Fourier Rework
Iodine Distinction Media
Ionizing Radiation
Inverse Sq. Legislation
Iterative Reconstruction
Iterative Reconstruction in Picture Area (IRIS)
#prime
J
Justification of Publicity
#prime
Okay
Okay-Edge Impact
Kerma
KERMA-Space Product (KAP)
Kernel, Filter
Klein-Nishina System
#prime
L
Landmarking
Final-Picture-Maintain (LIH)
Lead Apron
Lead Oxide
Lead Spectacles
Lens of the Eye, Damage
Gentle Beam Diaphragm
Limiting Spatial Decision
Linear Attenuation Coefficient
Linear Interpolation, Helical CT
Line Focus Precept
Line Unfold Perform (LSF)
Liquid Crystal Show (LCD)
Log-Median Index (LgM)
Logarithmic Transformation, CR & DR
Logarithmic Transformation, DSA
Lossless Compression
Low Frequency Drop (LFD)
Low-Move Filter
#prime
M
Mammography
Mammography, AEC
Mammography, Auto-kV
Mammography, CCD
Mammography, Compression
Mammography, Grids
Mammography, Magnification
Mammography, Photon Counting
Mammography, Scatter Discount
Mammography, Screening
Mammography, Slot-Scanning
Mammography, Stereotactic Imaging
Mass Attenuation Coefficient
Matched Filtration
Matrix Array, CT Detectors
Most Depth Projection (MIP), 2D
Most Depth Projection (MIP), 3D
Median Filter
Minification Achieve
Minimal Depth Projection (MinIP)
Modulation Switch Perform (MTF)
Moiré Sample
Multi-Detector Computed Tomography (MDCT)
Multi-Planar Reconstruction (MPR)
Multi-Slice CT (MSCT)
Multi-Slice Filtered Interpolation (MFI)
Multi-Slice Linear Interpolation (MLI)
A number of Beam Equalization Radiography (AMBER)
Multi-Scale Picture Distinction Amplification (MUSICA)
Mutual Data Maximization
#prime
N
Noise, Picture
Nyquist Frequency
#prime
O
Indirect Reconstruction
Opacity, Quantity Rendering
Optimization of Safety
Output Phosphor
Over-Sofa XRT
Over-Ranging, MDCT
#prime
P
Parallel Projection, 3D
Affected person Dose, Radiography
Affected person Dose, Fluoroscopy
Peak Pores and skin Dose
Penumbra
Perceptual Oscillation
Perspective Projection, 3D
Phosphor, Structured
Phosphor, Unstructured
Photocathode
Photoconductor
Photoconductive Video Digicam
Photoelectric Impact
Photoelectron
Photon Counting, Mammography
Picture-Stimulable Luminescence (PSL)
Decide-Up Tube (PUT)
Image Archival & Communication Methods (PACS) – Fundamentals; Particulars
Pitch, Grid
Pitch, Helical CT
Pixel
Pixelation
Pixel Worth
Plumbicon
Level Unfold Perform (PSF)
Poisson Distribution
Polychromatic Radiation
Energy Ranking, XRT
Main Photons
Main Radiation
Progressive Raster Scan
Projected Thickness
Pulsed Fluoroscopy
Pulsed Progressive Readout (PPR)
#prime
Q
Quantification, DSA
Quantization Error
Quantum Noise
#prime
R
Radio-Adaptive Response
Radiation Biology
Radiation Dose
Radiation Dose Administration
Radiation Hormesis
Radiation-Induced Bystander Response
RADs
Radiation Weighting Issue
Radiation Safety
Radiography Methods
Ramachandran & Lakshminarayana (Ram-Lak) Filter
Uncommon-Earth Filter
Raster Scan, Interlaced
Rebinning Algorithms, MDCT Reconstruction
Receiver Working Attribute (ROC)
Recoil Electron
Recursive Filtration
Area Progress, Picture Segmentation
REMs
Remasking
Reregistration
Retake Evaluation
Roadmapping
Roentgen, unit
Roentgen, Wilhelm
Rotating Anode XRT
Rotating Envelope XRT
Rotational Angiography
#prime
S
Sagittal Reconstruction
Sampling Frequency
Scanned Projection Radiography
Scatter Correction, Computerised
Scatter, Impact on Distinction
Scatter Discount
Scatter Discount, Mammography
Scattered Photons
Scatter-to-Main Ratio (SPR)
Screening, Mammography
Scrub Body
Secondary Electrons
Secondary Photons
Semiconductor Video Digicam
Sensitivity Index (SI)
Shaded Floor Show (SSD)
Sharpening
Shepp-Logan Filter
Sievert (Sv)
Sign-to-Noise Ratio (SNR)
Pores and skin Damage
Slot-Scanning
Smoothing
Sodium Iodide
Software program
Spatial Area Processing
Spatial Frequency
Spatial Frequency Processing
Spatial Interval
Spatial Decision
Spectral Filtration
Spiral CT
Sq. Wave Response (SWR)
Workers Dose
Stereotactic Imaging, Mammography
Stochastic Well being Threat
Storage Phosphor
Topic Distinction
Floor Rendering
Sync Pulse
#prime
T
Goal, Video Digicam
Temporal Filtration
Temporal Decision
Thermionic Emission
Thermoluminescence
3D Visualization
3D Multi-Planar Reconstruction
Thick Slab Projection
Threshold Definition, Picture Segmentation
Thyroid Protect
Time-Interval-Distinction (TID) imaging in DSA
Tissue Attenuation
Tissue Harm
Tissue Weighting Issue
Whole Filtration
True Cone-Beam Tomography (TCOT), MDCT
Switch Attribute
Tube Loading Curves, XRT
Two-Dimensional FFT
#prime
U
Extremely-Quick Ceramic (UFC) Detectors
Umbra
Underneath-Sofa XRT
Unsharp Masking
#prime
V
Vascular Hint
Veiling Glare
Video Digicam
Video Sign
Vidicon
Digital Collimation
Digital Colonoscopy
Digital Endoscopy
Visualization, 3D
Quantity Rendering, 2D
Quantity Rendering, 3D
Quantity Tomographic Angiography
Voxel
#prime
W
Weighted Hyperplane Reconstruction (MHR), MDCT
Wiener Spectrum
Windowing
#prime
X
XII-Video Methods
X-Ray Vitality Spectrum – Fundamentals; Particulars
X-Ray Picture Intensifier (XII)
X-Ray Shadows
X-Ray Tube (XRT) – Fundamentals; Particulars
X-Ray Tube Present (mA)
XRT Anode – Tungsten, Molybdenum, Rhodium
XRT, Cooling Curves
XRT, Heating Capability
XRT, Heating Curves
XRT, Energy Ranking
XRT, Rotating Envelope
XRT, Tube Loading Curves
Y
#prime
Z
z-Projection